Meeting Summary - 01/09/2025 ROS Meeting - Webex Only

Grid Monitor AI
01/09/2025

<p><img src="/storage/docs/2025/01/1-9-25-ROS-Hero.png" /></p> <h2><a href="/sharing/?token=fbcdb782-ad92-498f-b7f8-a5a099c49fc9"><span style="font-weight: 400;">▶️</span></a><span style="font-weight: 400;"> 0 - Validation for ROS Standing Representatives - Suzy Clifton</span></h2> <h2><a href="/sharing/?token=1f266ece-95f8-4550-a831-8ed7c66785d3"><span style="font-weight: 400;">▶️</span></a><span style="font-weight: 400;"> 1 - Antitrust Admonition - Suzy Clifton</span></h2> <h2><a href="/sharing/?token=5f4651f5-d89e-4b35-bfe8-e2b799eec44f"><span style="font-weight: 400;">▶️</span></a><span style="font-weight: 400;"> 2 - Election of 2025 ROS Chair and Vice Chair - Vote - Suzy Clifton</span></h2> <ul> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Introduced newly seated representatives: Tony Kroskey (Brazos), Shane Thomas (Shell), Justin Cockrell (DC Energy), and Dinesh Ramachandran (NG Renewables Energy Marketing).</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Chase Smith nominated Katie Rich from Vistra Energy for ROS 2025 Chair.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Katie Rich accepted the nomination.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">No additional nominations for Chair were received, so Katie Rich was elected as ROS 2025 Chair by acclamation.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Eithar Nashawati nominated Sandeep Borkar with LCRA for ROS 2025 Vice Chair.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Sandeep Borkar accepted the nomination.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">No additional nominations for Vice Chair were received, so Sandeep Borkar was elected as ROS 2025 Vice Chair.</span></li> </ul> <h2><a href="/sharing/?token=13747568-297c-4d1c-a5cb-dc6868930dce"><span style="font-weight: 400;">▶️</span></a><span style="font-weight: 400;"> 3 - Agenda Review - ROS Leadership</span></h2> <h2><a href="/sharing/?token=92b54cdb-6dbd-42ae-bda7-893d0fab3a07"><span style="font-weight: 400;">▶️</span></a><span style="font-weight: 400;"> 4 - Approval of ROS Meeting Minutes - Possible Vote - ROS Leadership</span></h2> <ul> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Motion to approve as submitted the November 7, 2024 Meeting Minutes added to the combo ballot.&nbsp;</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Motion to approve as submitted the December 5, 2024 Meeting Minutes added to the combo ballot.&nbsp;</span></li> </ul> <h2><a href="/sharing/?token=07f67722-5ba8-4279-b979-7b722fe30269"><span style="font-weight: 400;">▶️</span></a><span style="font-weight: 400;"> 5 - ERCOT Reports</span></h2> <h3><a href="/sharing/?token=2e585df3-34e3-4fce-b6af-82f6d16c281f"><span style="font-weight: 400;">▶️</span></a><span style="font-weight: 400;"> 5.1 - Operations Report - Freddie Garcia</span></h3> <ul> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">ERCOT's November 2024 unofficial peak demand was recorded at 60,170 megawatts, an increase of 3,635 megawatts from November 2023.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Three OCNs were issued in November: one for a topology change in the Panhandle IROL region, and two anticipating possible future emergency conditions.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">A new PVGR penetration record of 44.17% was set on November 20th at 14:55.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Inconsistencies were identified in the largest net load ramp table for 2016-2020, which have now been corrected.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Freddie Garcia confirmed there were no reliability risks associated with the new PVGR penetration record, and generation was sufficient to meet demand.</span></li> </ul> <h3><a href="/sharing/?token=624339e8-24ea-4b2b-978f-0a8f77730048"><span style="font-weight: 400;">▶️</span></a><span style="font-weight: 400;"> 5.2 - System Planning Report - Ping Yan</span></h3> <ul> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">All ERCOT end-of-year reports have been posted on the ERCOT website.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Reports include:</span></li> <ul> <li style="font-weight: 400;" aria-level="2"><span style="font-weight: 400;">Constraints and Needs Report</span></li> <li style="font-weight: 400;" aria-level="2"><span style="font-weight: 400;">Regional Transmission Plan Report</span></li> <li style="font-weight: 400;" aria-level="2"><span style="font-weight: 400;">Long Term System Assessment Report</span></li> <li style="font-weight: 400;" aria-level="2"><span style="font-weight: 400;">Grid Reliability and Resilience Assessment Report</span></li> </ul> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">ERCOT will hold an EHV 765 workshop on January 27th to discuss the 765 plan.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">The new Grid Reliability and Resilience Assessment Report is a requirement from Senate Bill 1281, and ERCOT is required to perform this assessment every other year.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">The assessment studied two extreme weather scenarios:</span></li> <ul> <li style="font-weight: 400;" aria-level="2"><span style="font-weight: 400;">A winter peak scenario similar to the 2021 Uri storm</span></li> <li style="font-weight: 400;" aria-level="2"><span style="font-weight: 400;">A Category 5 hurricane scenario hitting Houston</span></li> </ul> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Findings suggest that transmission enhancements are needed to reduce load loss and prevent system cascading events.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">For the winter peak scenario, ERCOT found a need to enhance import paths to Central Texas and between South Dallas and Central Texas.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">For the hurricane scenario, substation hardening is crucial in reducing the impact on the Texas grid and consumers.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Ping Yan suggested that results could be further discussed in the January RPG meeting.</span></li> </ul> <h2><a href="/sharing/?token=1f6eee0e-d2d9-4241-a271-32e309daeef0"><span style="font-weight: 400;">▶️</span></a><span style="font-weight: 400;"> 6 - ROS Revision Requests - Vote - ROS Leadership</span></h2> <ul> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">The discussion for agenda item number 6 was combined with item number 7.</span></li> </ul> <h3><a href="/sharing/?token=50360962-7b4d-4b08-b29c-d873e7e51207"><span style="font-weight: 400;">▶️</span></a><span style="font-weight: 400;"> 6.1 - NOGRR271, Related to NPRR1257, Limit on Amount of RRS a Resource can Provide Using Primary Frequency Response - Possible Vote</span></h3> <ul> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Motion to endorse and forward to TAC the 12/5/2024 ROS Report and 10/21/24 Impact Analysis for NOGRR271 added to the combo ballot.</span></li> <ul> <li style="font-weight: 400;" aria-level="2"><span style="font-weight: 400;">IA identified as having no cost and no impact.</span></li> </ul> </ul> <h3><a href="/sharing/?token=bf4f2767-1a7f-4ae7-a870-228c93694f2b"><span style="font-weight: 400;">▶️</span></a><span style="font-weight: 400;"> 6.2 - NOGRR273, Related to NPRR1264, Creation of a New Energy Attribute Certificate Program</span></h3> <ul> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Motion to table NOGRR273 added to the combo ballot.</span></li> </ul> <h3><a href="/sharing/?token=8ea02c0c-cab9-42c9-8c3a-c1c3ddfe983b"><span style="font-weight: 400;">▶️</span></a><span style="font-weight: 400;"> 6.3 - PGRR123, Related to NPRR1264, Creation of a New Energy Attribute Certificate Program</span></h3> <ul> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Motion to table PGRR123 added to the combo ballot.</span></li> </ul> <h3><a href="/sharing/?token=5f72faa1-9b47-4073-9a76-cd08d40be1df"><span style="font-weight: 400;">▶️</span></a><span style="font-weight: 400;"> 6.4 - RRGRR038, Related to NPRR1264, Creation of a New Energy Attribute Certificate Program</span></h3> <ul> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Motion to table RRGRR038 added to the combo ballot.</span></li> <ul> <li style="font-weight: 400;" aria-level="2"><span style="font-weight: 400;">NPRR1264 aims to expand the existing energy attribute certificate program to include more participants.</span></li> <li style="font-weight: 400;" aria-level="2"><span style="font-weight: 400;">WMS voted to table all their items and suggested evaluating NPRR1264 and related revision requests in detail.</span></li> <li style="font-weight: 400;" aria-level="2"><span style="font-weight: 400;">There is a suggestion to let WMS work on the program design before reviewing for reliability concerns.</span></li> </ul> </ul> <h2><a href="/sharing/?token=5c0be6dc-b556-41c2-a881-bb0990c74087"><span style="font-weight: 400;">▶️</span></a><span style="font-weight: 400;"> 7 - NPRR1264, Creation of a New Energy Attribute Certificate Program - Possible Vote - ROS Leadership</span></h2> <ul> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Motion to request PRS to table NPRR1264 added to the combo ballot.</span></li> <ul> <li style="font-weight: 400;" aria-level="2"><span style="font-weight: 400;">Introduction of NPRR1264 as a new certificate program replacing the traditional REC program.</span></li> <li style="font-weight: 400;" aria-level="2"><span style="font-weight: 400;">One revision request related to NPRR1264 remains tabled.</span></li> <li style="font-weight: 400;" aria-level="2"><span style="font-weight: 400;">Discussion of various working groups: OWG, NDSWG, PLWG, DWG, IBRWG.</span></li> <li style="font-weight: 400;" aria-level="2"><span style="font-weight: 400;">Combo ballot mentioned, indicating grouped non-voting items.</span></li> <li style="font-weight: 400;" aria-level="2"><span style="font-weight: 400;">Consideration of leadership appointments for working groups, with some positions already filled.</span></li> </ul> </ul> <h2><a href="/sharing/?token=bce81537-81a0-4f3d-9c82-21f7d8751889"><span style="font-weight: 400;">▶️</span></a><span style="font-weight: 400;"> 8 - Revision Requests Tabled at PRS and Referred to ROS - Possible Vote - ROS Leadership</span></h2> <h3><a href="/sharing/?token=e5205719-b76c-461e-92d1-a794b22f1ea3"><span style="font-weight: 400;">▶️</span></a><span style="font-weight: 400;"> 8.1 - NPRR1229, Real-Time Constraint Management Plan Energy Payment</span></h3> <ul> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">The decision is to leave NPRR1229 tabled to see what happens when it exits WMWG.</span></li> </ul> <h2><a href="/sharing/?token=c22c0106-d8c3-49d6-8db4-a35c764b2c85"><span style="font-weight: 400;">▶️</span></a><span style="font-weight: 400;"> 9 - Revision Requests Tabled at ROS - Possible Vote - ROS Leadership</span></h2> <ul> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Agenda item 9 is a long-standing tabled item.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">No questions were raised regarding this agenda item.</span></li> </ul> <h2><a href="/sharing/?token=c8d4b50a-db71-4c43-a9ed-49d02a2855b8"><span style="font-weight: 400;">▶️</span></a><span style="font-weight: 400;"> 10 - Operations Working Group - OWG - Rickey Floyd</span></h2> <h3><a href="/sharing/?token=e3182795-38dd-4d08-8732-c9fc2862a8f1"><span style="font-weight: 400;">▶️</span></a><span style="font-weight: 400;"> 10.2 - NPRR1238, Voluntary Registration of Loads with Curtailable Load Capabilities - OWG - Possible Vote</span></h3> <ul> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Close to finalizing; expect to file comments in 2 to 3 weeks.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Collaboration with Golden Spread mentioned.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">OWG meeting scheduled for Monday; expect comments on NPRR1238 during this meeting.</span></li> </ul> <h3><a href="/sharing/?token=fbf1eea2-e203-4244-8686-be17012a4698"><span style="font-weight: 400;">▶️</span></a><span style="font-weight: 400;"> 10.3 - NOGRR265, Related to NPRR1238, Voluntary Registration of Loads with Curtailable Load Capabilities - OWG - Possible Vote</span></h3> <ul> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">A quick status update was provided on NOGRR265.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">NOGRR265 is related to NPRR1238 concerning voluntary registration of loads with curtailable load capabilities.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">The topic was discussed by the Operating Working Group (OWG).</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">There is potential for a vote on the matter.</span></li> </ul> <h2><a href="/sharing/?token=3a8a3bd0-e72d-47e5-8948-78a64370face"><span style="font-weight: 400;">▶️</span></a><span style="font-weight: 400;"> 11 - Network Data Support Working Group - NDSWG - Gerardo Escamilla</span></h2> <h3><a href="/sharing/?token=67051d24-2de0-48b5-abf8-bee65138bfca"><span style="font-weight: 400;">▶️</span></a><span style="font-weight: 400;"> 11.1 - NPRR1234, Interconnection Requirements for Large Loads and Modeling Standards for Loads 25 MW or Greater - NDSWG - Possible Vote</span></h3> <p><a href="/storage/docs/2025/01/11-ndswg_report_to_ros_010925.pdf"><span style="font-weight: 400;">11-ndswg_report_to_ros_010925.pdf</span></a></p> <ul> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Highlighted an ongoing discussion about the defined term for "transmission service bus" proposed in NPRR1234.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">The defined term is primarily relevant to PGRR115 and may require additional comments for modification or removal.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Comments on PGRR115 are expected to be filed within 1&ndash;2 weeks.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Suggestion to keep NPRR1234 tabled for one more month.</span></li> </ul> <h2><a href="/sharing/?token=a4733cfe-b0ae-42d8-aa70-464d9e2deea2"><span style="font-weight: 400;">▶️</span></a><span style="font-weight: 400;"> 12 - Planning Working Group - PLWG - Dylan Preas</span></h2> <p><a href="/storage/docs/2025/01/12-planning-working-group-report_01092025.pdf"><span style="font-weight: 400;">12-planning-working-group-report_01092025.pdf</span></a></p> <ul> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Mina Turner was nominated as PLWG chair for 2025, currently vice chair for 2024.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Kristin Cook was nominated as vice chair, noted for active participation in PLWG.</span></li> </ul> <h3><a href="/sharing/?token=6076f80c-b7cb-42ab-b825-73b75057bbc6"><span style="font-weight: 400;">▶️</span></a><span style="font-weight: 400;"> 12.1 - PGRR115, Related to NPRR1234, Interconnection Requirements for Large Loads and Modeling Standards for Loads 25 MW or Greater - PLWG - Possible Vote</span></h3> <ul> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">In December, comments and discussions focused on disconnecting large industrial loads and establishing stability and steady screening thresholds.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">There was talk about including criteria for a standalone 1,000 MW load interconnection.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">PLWG decided to table the discussion for additional follow-up at the January meeting due to ongoing discussions and the need for responses to comments.</span></li> </ul> <h3><a href="/sharing/?token=f4562efe-4953-4a65-aab6-75556c67fc6e"><span style="font-weight: 400;">▶️</span></a><span style="font-weight: 400;"> 12.2 - PGRR119, Stability Constraint Modeling Assumptions in the Regional Transmission Plan - PLWG - Possible Vote</span></h3> <ul> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">The item was taken back from the last ROS for further comments from joint commenters.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">ERCOT will collaborate with joint commenters to refine the language of the item.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">The discussion on this item was tabled pending further discussion in January.</span></li> </ul> <h3><a href="/sharing/?token=6ea8f7e2-cbe2-418b-b0f1-6cca0dba706c"><span style="font-weight: 400;">▶️</span></a><span style="font-weight: 400;"> 12.3 - PGRR120, SSO Prevention for Generator Interconnection - PLWG - DWG - Possible Vote</span></h3> <ul> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Southern Power submitted comments on the proposal.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Proposed addition: Allowing existing generation resources to modify interconnection to a series compensated line if SSO is mitigated.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">ERCOT requested more time to review comments.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">The item was tabled for further discussion in January.</span></li> </ul> <h3><a href="/sharing/?token=118bfcff-ffdb-458e-a9b1-7d9189dd46de"><span style="font-weight: 400;">▶️</span></a><span style="font-weight: 400;"> 12.4 - PGRR122, Reliability Performance Criteria for Loss of Load - DWG - PLWG - Possible Vote</span></h3> <ul> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Introduction of PGRR122, which adds planning criteria to limit the total loss of load to less than 1000 megawatts under ERCOT and NERC reliability criteria.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Discussion on including NERC P6 standards and potential overlap with events defined in PGRR115.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">The PLWG tabled PGRR122 for further discussion in January.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Tracking of NERC standards CIP-013 and TPL-008 which affect planners.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">An ongoing action item to review and revise the use of 'load' in the planning guide for alignment with protocol section 2, continuing in planning working group meetings.</span></li> </ul> <h2><a href="/sharing/?token=d8263b57-2dad-4275-b413-56a6f7552775"><span style="font-weight: 400;">▶️</span></a><span style="font-weight: 400;"> 13 - Dynamics Working Group - DWG - Paul Koberlein.</span></h2> <p><a href="/storage/docs/2025/01/13-dwg-report-to-ros-january-2025.pdf"><span style="font-weight: 400;">13-dwg-report-to-ros-january-2025.pdf</span></a></p> <ul> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Concerns were raised about the current language of PGRR122, specifically regarding ownership responsibilities.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Issues were identified around TSPs potentially being unable to fulfill required duties due to ownership complications.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">The group decided to table PGRR122 for further review.</span></li> </ul> <h3><a href="/sharing/?token=4f6e5229-9b8d-4755-85ef-f61d0d5861b7"><span style="font-weight: 400;">▶️</span></a><span style="font-weight: 400;"> 13.1 - NOGRR272, Advanced Grid Support Requirements for Inverter-Based ESRs - DWG - IBRWG - Possible Vote</span></h3> <ul> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Discussion to continue in February on PGRR121 and NOGRR272 due to the need for a more detailed review.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Potential PGRR for SSWG case security was presented, feedback will be provided.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Texas RE completed the 2024 case quality metrics assessment with improvements in some metrics; recommendations left for focus areas.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Opposition to PGRR120 was noted; further discussion planned to address concerns.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Potential update to SSR study scope guidelines to be discussed in the next meeting.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Flat start case development update nearly complete, targeting approval by January 2025.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Modeling and stability discussions progressing with suggestions being solicited for comments.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">2025 DWG meeting schedule posted on the DWG landing page.</span></li> </ul> <h3><a href="/sharing/?token=fc877f6f-60db-496a-99d1-b496232b459f"><span style="font-weight: 400;">▶️</span></a><span style="font-weight: 400;"> 13.2 - PGRR121, Related to NOGRR272, Advanced Grid Support Requirements for Inverter-Based ESRs - DWG - IBRWG - Possible Vote</span></h3> <ul> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Fred Huang from ERCOT discussed NOGRR272 and PGRR121, focusing on large amounts of IVRs on the grid and stability challenges.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Talked about solutions for stability issues, including synchronous condensers and inverter-based resources.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Discussed the development of advanced grid support capabilities for batteries with benefit studies beginning in 2023.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Mentioned NERC's two white papers on grid forming technology and specifications for grid forming batteries.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">ERCOT is working on a testing framework with engaged electronics to adopt this technology, forming the basis for NOGRR and PGRR.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Outlined benefits of grid forming technology such as transient dynamic voltage and frequency response improvements.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">ERCOT noted no additional hardware or overload capacity is required for these requirements, fitting within planned equipment ratings.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">No energy market dispatch changes are required under the current proposals.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">NOGRR provides a high-level requirement definition, while PGRR adds modeling details.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">ERCOT is working on a DWG procedure manual update to include the testing framework, anticipating discussion in February.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">All tests are simulation-based with no envisioned physical commissioning tests.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Implementation timelines are flexible, with ERCOT working with stakeholders on reasonable dates.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Some projects in weak grid areas are adopting advanced grid support capabilities before official approval.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Fred Huang provided a global update on grid forming capabilities with examples from other system operators and manufacturers.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Discussion included procurement strategies, e.g., Hawaii's competitive RFP process for grid forming batteries.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Inertia markets were mentioned; ERCOT sees stable inertia levels, with benefits seen in weak grid scenarios.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Michael Jewell raised timelines issues comparing European and proposed ERCOT timelines.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Manufacturers will be invited to present on their advanced grid forming capabilities and related challenges.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Coordination between IBRWG and DWG was discussed with testing frameworks and procedure manual updates in progress.</span></li> </ul> <h3><strong>Next Steps</strong></h3> <ul> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Continuing to discuss and refine PGRR and NOGRR requirements at IBRWG meetings.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Inviting manufacturers for discussion on January 17th on capabilities and limitations.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Coordinating a DWG and IBRWG session in February for further testing framework review.</span></li> </ul> <h2><a href="/sharing/?token=c9c4246d-1327-4603-aca6-08227ae11212"><span style="font-weight: 400;">▶️</span></a><span style="font-weight: 400;"> 14 - Inverter Based Resources Working Group - IBRWG - Julia Matevosyan</span></h2> <p><a href="/storage/docs/2025/01/14-ibrwg-report-to-ros-010925.pdf"><span style="font-weight: 400;">14-ibrwg-report-to-ros-010925.pdf</span></a></p> <ul> <li style="font-weight: 400;" aria-level="1"><strong>Leadership:</strong><span style="font-weight: 400;"> Julia Matevosyan and Miguel Cova Acosta agreed to serve another year as chair and vice-chair respectively.</span></li> <li style="font-weight: 400;" aria-level="1"><strong>NERC Updates:</strong><span style="font-weight: 400;"> NERC projects, part of FERC order 901 related to IVR performance and monitoring, have been submitted before the deadline fulfilling milestone 2.</span></li> <li style="font-weight: 400;" aria-level="1"><strong>Current and Upcoming NERC Projects:</strong><span style="font-weight: 400;"> Projects are moving towards milestone 3, focusing on modeling, including EMT modeling. A technical conference is scheduled for January 15th-16th.</span></li> <li style="font-weight: 400;" aria-level="1"><strong>TRE SAR for BAL-001-TRE:</strong><span style="font-weight: 400;"> Clarifying roles and PFR performance for batteries. Does not address deep core payments and wind generation performance.</span></li> <li style="font-weight: 400;" aria-level="1"><strong>ERCOT's IVR Category 2:</strong><span style="font-weight: 400;"> Resources of 20-75 MW must register with NERC by May 2025-2026.</span></li> <li style="font-weight: 400;" aria-level="1"><strong>NERC Level 2 IVR Modeling Alert:</strong><span style="font-weight: 400;"> NERC has received and analyzed responses. TRE will present findings at the January IBRWG meeting.</span></li> </ul> <h2><a href="/sharing/?token=51da8fff-85bc-42d5-ac6d-1464b8d790b4"><span style="font-weight: 400;">▶️</span></a><span style="font-weight: 400;"> 15 - Combo Ballot - Vote - ROS Leadership</span></h2> <ul> <li><span style="font-weight: 400;">Motion to approve combo ballot passed unanimously with no abstentions</span></li> </ul> <p><img src="/storage/docs/2025/01/1-9-25-ROS-ComboBallotItems.png" width="767" height="212" /></p> <h2><span style="font-weight: 400;">&nbsp;<img src="/storage/docs/2025/01/1-9-25-ROS-Ballotresults.png" width="746" height="762" /></span></h2> <h2><a href="/sharing/?token=95dcf22f-5e7b-4ee3-8664-310ff6b9210c"><span style="font-weight: 400;">▶️</span></a><span style="font-weight: 400;"> 16 - Black Start Working Group - BSWG - Michael Dieringer</span></h2> <ul> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">A meeting took place in December for the group.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">The next meeting is anticipated around March.</span></li> </ul> <h2><a href="/sharing/?token=0b005386-d804-480e-b2aa-e4eda5a1aeda"><span style="font-weight: 400;">▶️</span></a><span style="font-weight: 400;"> 17 - Steady State Working Group - SSWG - William Robertson</span></h2> <p><a href="/storage/docs/2025/01/17-sswg-report-to-ros-1-9-2025.pdf"><span style="font-weight: 400;">17-sswg-report-to-ros-1-9-2025.pdf</span></a></p> <ul> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Finalized the 2025 SSWG calendar; meetings available on the SSWG landing page.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">TPIT report posted on January 24th under MIS.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Starting 2025 SSWG case building process this month, with preparation beginning next week.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Expected publishing date for the first case build is in June.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">This is the second year cases will be in the node breaker format.</span></li> </ul> <h2><a href="/sharing/?token=8f465839-f8ea-4f5d-be5e-1dbf505fe7f7"><span style="font-weight: 400;">▶️</span></a><span style="font-weight: 400;"> 18 - Operations Training Working Group - OTWG - Manuel Sanchez</span></h2> <p><a href="/storage/docs/2025/01/18-january_otwg_updates.pdf"><span style="font-weight: 400;">18-january_otwg_updates.pdf</span></a></p> <ul> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">ERCOT has closed agreements with a new vendor provider for the operator certification exam, transitioning from a previous vendor.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">The new testing platform will be fully remote using local proctors.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Communication and training will be provided for exam facilitation.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">ERCOT operations training group will undergo training to familiarize with the new platform.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">2024 in-person Black Start seminar was successfully completed.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">ERCOT completed CEH processing for market participants who completed training.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">A computer-based Black Start training will be released by ERCOT's learning center.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">The operations training seminar schedule is in progress with tentative dates identified.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">A pilot session is planned for presenters to facilitate class schedules.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">No emergency training is scheduled for this year's operations training seminar.</span></li> </ul> <h2><a href="/sharing/?token=770ffb61-ab5b-4587-9950-f05b6683c4bc"><span style="font-weight: 400;">▶️</span></a><span style="font-weight: 400;"> 19 - Other Business - ROS Leadership</span></h2> <h3><a href="/sharing/?token=0c92b32b-0d92-4768-85ee-20f53caf8cce"><span style="font-weight: 400;">▶️</span></a><span style="font-weight: 400;"> 19.1 - 2025 ROS Goals</span></h3> <p><a href="/storage/docs/2025/01/19-2024-ros-goals-tac-approved-03272024.pdf"><span style="font-weight: 400;">19-2024-ros-goals-tac-approved-03272024.pdf</span></a></p> <ul> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Review of ROS goals is anticipated to align with TAC decisions.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Participants were advised to prepare thoughts on ROS goals for the February meeting.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Upcoming discussion on ROS working group leadership for the current year.</span></li> </ul> <h3><a href="/sharing/?token=8cea2fc1-4506-4f21-835f-bfb462bd15fa"><span style="font-weight: 400;">▶️</span></a><span style="font-weight: 400;"> 19.2 - 2025 ROS Working Group Leadership</span></h3> <ul> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Participants reminded to submit nominees for chair and vice chair positions.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">A formal email was sent by Suzy Clifton for responses regarding leadership nominations.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Aim to complete the leadership table to identify any open seats.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Reminder to have materials prepared and reviewed before the ROS meeting.</span></li> </ul> <h3><a href="/sharing/?token=a7a21780-5de1-44fb-971f-c3f2e6ba08e5"><span style="font-weight: 400;">▶️</span></a><span style="font-weight: 400;"> 19.3 - Review Open Action Items List</span></h3> <ul> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Suzy Clifton updated the items; some require confirmation to be removed.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Updates discussed in the NDSWG handbook; still under review.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">PLWG provided an update on their progress.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Susana Hildebrand to present on EPA issues at the January 30th WWG meeting.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">EEA2 event item removed; parking lot item KTC 15.15 Black Start Service remains.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Approval process described for removing items upon TAC confirmation.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Meetings scheduled through August and Webex conflicts noted.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Chase Smith raised questions about NOGRR245 implementation; ERCOT's Agee Springer provided expected timelines for information release and workshop scheduling.</span></li> <li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Discussion on RFI results for PUN issue; Fred Huang provided a status update.</span></li> </ul> <h2><a href="/sharing/?token=4b452e11-ee1a-4919-8c04-99dfe929a65b"><span style="font-weight: 400;">▶️</span></a><span style="font-weight: 400;"> 20 - Adjourn - ROS Leadership</span></h2> <p><span style="font-weight: 400;">&nbsp;</span></p> <p><br /><br /></p>