<p><span style="font-weight: 400;"><img src="/storage/docs/2024/09/20240916IBRWGHero.png" width="871" height="672" /></span></p>
<p><span style="font-weight: 400;">1 - Antitrust Admonition Julia Matevosyan</span></p>
<p><a href="/sharing/?token=c99c9a45-1744-42ec-aafb-44afa083fe13"><span style="font-weight: 400;">2</span></a><span style="font-weight: 400;"> - DWG Procedure Manual S.-W. Kang</span></p>
<ul>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">ERCOT appreciates stakeholder support and addressed all comments on the DWG precision manuals.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Draft DWG procedure manual posted on DWG website.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">PUCT decision on NPRR245 expected in September; effective date likely October 1.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">ROS approval sought on October 3, previously planned for September.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Updated DWG manual available on the website as a draft for familiarization.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">ERCOT updated PMV and DMV tools for NPRR245 writethrough test.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Tools are linked in previous meeting presentations and ERCOT model quality guide.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Confirmations received from Jonathan on PMV and DMV tool updates with latest NOGRR245 test proposals.</span></li>
</ul>
<p><a href="/sharing/?token=fe894bd9-56e0-4715-bbfa-bc319d168d68"><span style="font-weight: 400;">3</span></a><span style="font-weight: 400;"> - NERC Standards Update FERC Order 901 M. Henry TRE</span></p>
<ul>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Brief </span><a href="https://ercot-control-docs.s3.us-west-2.amazonaws.com/13/240912%2520NERC%2520901%2520IBR%2520Stds%2520Update.pdf"><span style="font-weight: 400;">update</span></a><span style="font-weight: 400;"> on NERC standards related to FERC order 901</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">FERC directives to NERC in October 2023 to address IBR integration challenges</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Four focus areas: data sharing, model validation, planning, operational studies, IVR performance requirements</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Milestone 2 projects to be completed by November 4</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Three projects involved in Milestone 2</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Details on the first project: Disturbance monitoring equipment (2021-04) leading to PRC-028-1 standard</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">PRC-024 version 5 IBR-related material moved to PRC-029, consensus issues</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Technical Conference held by NERC to gather feedback on PRC-029</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Workshop findings: difficulty meeting requirements with older equipment, technical challenges, and OEM feedback</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">New standard PRC-030 asking entities to evaluate and mitigate issues</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">New standards expected to be issued for final ballot</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">NERC board may step in if consensus is not reached</span></li>
</ul>
<p><span style="font-weight: 400;">Questions Asked:</span></p>
<ul>
<li style="font-weight: 400;" aria-level="1"><strong>Name:</strong><span style="font-weight: 400;"> John Schmall</span><span style="font-weight: 400;"><br /></span><strong>Question:</strong><span style="font-weight: 400;"> Who is responsible for drafting the revised standard for PRC-029?</span><span style="font-weight: 400;"><br /></span><strong>Answer:</strong><span style="font-weight: 400;"> NERC staff most likely driving it with the standards committee.</span></li>
<li style="font-weight: 400;" aria-level="1"><strong>Name:</strong><span style="font-weight: 400;"> Ken Donohoo</span><span style="font-weight: 400;"><br /></span><strong>Question:</strong><span style="font-weight: 400;"> Clarification on proposed standards exceeding IEEE 2800 and concerns over legacy equipment</span><span style="font-weight: 400;"><br /></span><strong>Answer:</strong><span style="font-weight: 400;"> Acknowledgment that proposed standards go beyond IEEE 2800; consideration for legacy equipment being discussed.</span></li>
</ul>
<p><span style="font-weight: 400;">Next Steps:</span></p>
<ul>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">NERC to issue new standard for ballot with a quick turnaround</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Further outreach and discussions to address concerns</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Update on implementation timelines after FERC approval</span></li>
</ul>
<p><a href="/sharing/?token=b4fa9af6-99db-4664-ae9e-e9545df043a6"><span style="font-weight: 400;">4</span></a><span style="font-weight: 400;"> - Draft Proposal for Advanced Grid Support Energy Storage Resource F. Huang ERCOT</span></p>
<ul>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Fred Huang from ERCOT provided an update on a planned revision request.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Three key documents were posted: draft NOGRR, draft PGRR, and the pace framework report.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Electronics consultant recommended eleven tests for gridforming technology; narrowed down to seven proposed test requirements.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Potential impact on the grid includes improved system voltage and frequency response during events, and increased stability in areas with advanced grid support energy storage.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">The proposal mainly focuses on energy storage resources currently but may extend to other inverter-based resources like wind and solar in the future.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">ERCOT aims to reinforce system reliability and support, responding to the growing penetration of inverter-based resources.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">New requirements will apply to energy storage with SGIS agreements signed on or after April 1, 2025.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Seven model quality tests to be introduced for energy storage resources to assess and verify advanced grid support.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">The proposed tests include:</span></li>
<ul>
<li style="font-weight: 400;" aria-level="2"><span style="font-weight: 400;">Flat start test</span></li>
<li style="font-weight: 400;" aria-level="2"><span style="font-weight: 400;">Small voltage disturbance test</span></li>
<li style="font-weight: 400;" aria-level="2"><span style="font-weight: 400;">Large voltage disturbance test</span></li>
<li style="font-weight: 400;" aria-level="2"><span style="font-weight: 400;">Frequency change and inertia response test</span></li>
<li style="font-weight: 400;" aria-level="2"><span style="font-weight: 400;">System strength test</span></li>
<li style="font-weight: 400;" aria-level="2"><span style="font-weight: 400;">Phase angle jump test</span></li>
<li style="font-weight: 400;" aria-level="2"><span style="font-weight: 400;">Loss of synchronous machine test</span></li>
</ul>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">The pace framework report elaborates on the functional specifications and the setup for the seven proposed tests.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Future directions include exploring similar requirements for wind and solar resources.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Further details may be presented in a work session in the next IBR working group meeting.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Stakeholders are encouraged to provide feedback before formal submission in October.</span></li>
</ul>
<p><a href="/sharing/?token=9c81d642-1b5b-4b7c-956a-43032f221bdf"><span style="font-weight: 400;">5</span></a><span style="font-weight: 400;"> - PFR from IBRs under “Deep” Curtailment M. Cova Acosta Vestas, Nick Miller Hickory Ledge, All</span></p>
<ul>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Miguel Acosta from Vestas highlighted key concerns regarding primary frequency response (PFR) from IBRs during deep curtailment.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Current frequency response standards like BAL TRE and its four defined zones were discussed.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Main issues identified: IBRs' failure to respond to under-frequency events when high curtailment or no power production exists.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Explanation of turbine operations during full curtailment and the time it takes to resume active power production.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">ERCOT's expectation is for primary frequency response within 16-60 seconds, which isn't met by turbines in a fully stopped state.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Miguel suggested two solutions: listing this situation as an exemption and creating realistic expectations for turbine capabilities in centralized systems.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Potential improvement with realistic telemetry data to facilitate grid operator expectations.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Nick Miller and other participants discussed the impact of NTON/NTOFF telemetry in relation to turbine readiness and its effect on grid support during frequency events.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">The impact of mechanical wear and tear due to frequent start-stop cycles of turbines was highlighted.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">A second limitation discussed was the technical minimum operating points and the need to configure plants to avoid turbines frequently pausing and restarting due to minor frequency deviations.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Potential solutions include setting a low sustained limit above zero or implementing filtering mechanisms to handle small frequency deviations.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Need for understanding how other OEMs handle frequency sampling and the importance of forums for open discussion.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">A final enhancement suggestion to improve IBR response, focusing on faster response capability and lack of inertia in IBRs.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Questions from participants covered issues such as commercial considerations, impact on models, and specific vendor differentiation.</span></li>
</ul>
<p><a href="/sharing/?token=e6ecf5d3-16b5-4080-a84e-d01446fdec10"><span style="font-weight: 400;">6</span></a><span style="font-weight: 400;"> - NOGRR245 Update S. Solis ERCOT</span></p>
<ul>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">NOGRR245 is expected to be reviewed by the commission this month, with hopes for approval.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">One of the commissioners had previously commented on monitoring NERC activities. Conversations with FERC staff about timelines were also noted.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">If regional needs exceed NERC standards, it's acceptable. There's a history of avoiding duplication of NERC rules but adapting them to meet ERCOT region requirements.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Internal drafts exist. Feedback from the commission will shape the next set of language. A new NOGRR will be submitted soon after approval.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Discussions will likely be held in the IBRWG for a month, but crucial conversations will occur in ROS and TAC forums.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Updates will be provided monthly to the IBRWG to keep all parties informed of developments.</span><span style="font-weight: 400;"><br /><br /></span></li>
</ul>
<p><a href="/sharing/?token=28f50df5-5c1c-4dc4-8ec6-01e306dddc1a"><span style="font-weight: 400;">7</span></a><span style="font-weight: 400;"> - RoCoF and Phase Jump Measurement Discussion M. Cova Acosta Vestas, S. Solis ERCOT, All</span></p>
<ul>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Discussed the importance of measurement methods for Rate of Change of Frequency (RoCoF) and phase angle jumps for determining protection system responses.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Previous presentations and literature indicate that measurements during transients/faults may not be reliable for RoCoF monitoring and tripping.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">IEEE 2800 suggests an averaging window of at least 0.1 seconds, but recent events showed this might not be sufficient.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Discussion on adopting an appropriate averaging window for the region, with ERCOT suggesting 0.5 seconds.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Highlighted that phase angle jumps should not trip during faults and require a different consideration for averaging windows.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Lacking feedback from generator owners, prompting further discussions and feedback collection.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Vestas shared their internal process for frequency calculation using LabVIEW software, highlighting the need to understand different measurement methods.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Concerns raised about moving averaging windows and how different calculation methods might affect RoCoF measurements and subsequent actions.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Emphasis on standardizing methods for calculating frequency and RoCoF to avoid different measurement expectations and improve coordination.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Understanding how frequency readings are processed from instantaneous waveforms is critical before determining new standards.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Comments on practical difficulties related to aligning different manufacturers' measurement methods.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Suggestion for OEMs to align with ERCOT's measurement methods to ensure consistent communication and compliance.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Need for transparency in methodology used by ERCOT for its RoCoF conclusions based on available PMU data.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Discussion on the potential pros and cons of extending or reducing the moving average filter window.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Importance of standardized methodologies to avoid discrepancies and ensure accurate RoCoF measurements across different equipment.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Planning a working session to further discuss and define methodologies and implementations for consistent measurement standards.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Acknowledgment of the need to progress towards solutions in a timely manner to align with implementation timelines.</span></li>
</ul>
<p><span style="font-weight: 400;">9 - Adjourn</span></p>
<ul>
<li style="font-weight: 400;" aria-level="1"> </li>
</ul>
<p><span style="font-weight: 400;"> </span></p>
<p><br /><br /></p>